Universal CST armoured Unitube Cable - Double Jacket (ZC)

Indoor/Outdoor Fibre optic cable with full protection against rodents for direct burial installation.

Fibre count 2 – 24
Fibre Type G.652.D, G.657.A1, G.657.A2, G.655, OM1, OM2, OM3, OM4, OM5
Fibre colour 1-12 Blue, Orange, Green, Brown, Grey, White, Red, Black, Yellow, Violet, Pink, Aqua
Fibre colour 13-24 BlueBS, OrangeBS, GreenBS, BrownBS, GreyBS, WhiteBS, RedBS, Natural, YellowBS, VioletBS, PinkBS, AquaBS
Tube colour Natural / White
Tube diameter 2.6 mm
Peripheral strength members Water-swellable Glass yarn
Ripcord 1x under inner jacket
Inner jacket UV resistant Halogen-free flame-retardant thermoplastic compound
Inner jacket thickness 0.8 mm
Outer jacket UV resistant Halogen-free flame-retardant thermoplastic compound
Outer jacket thickness 1.5 mm
Nominal outer diameter 10.0 mm
Cable Weight (calc.) 134 kg/km
BS Black strip
Max. tensile strength (Short Term) 1500 N EN 60794-1-21-E1(since 2024-02-19 new IEC 60794-1-101)
Max. tensile strength (Long Term) 450 N EN 60794-1-21-E1 (since 2024-02-19 new IEC 60794-1-101)
Crush resistance 3500 N/100 mm EN 60794-1-21-E3 (since 2024-02-19 new IEC 60794-1-103)
Max. Impact loading 25 Nm EN 60794-1-21-E4 (since 2024-02-19 new IEC 60794-1-104)
Min. bend radius not load 15 x OD EN 60794-1-21-E11 (since 2024-02-19 new IEC 60794-1-111)
Min. bend radius load 20 x OD EN 60794-1-21-E1 1(since 2024-02-19 new IEC 60794-1-111)
Operating temperature range -20°C to +70°C EN 60794-1-22-F1 (since 2024-02-19 new IEC 60794-1-201)
Storage temperature range -40°C to +70°C EN 60794-1-22-F1 (since 2024-02-19 new IEC 60794-1-201)
Installation temperature range -15°C to +50°C EN 60794-1-22-F1 (since 2024-02-19 new IEC 60794-1-201)
Water tightness No leakage EN 60794-1-22-F5C (since 2024-02-19 new IEC 60794-1-205)
Class of fire reaction Fca EN 50575, EN 13501-6

 

OPTOKON ChatBot